Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1178STBY-SPE (Standby SPE)
10
2024
(cont’d.)
ABORT 11. Issue the refresh spe-standby command to put the Standby SPE into
Standby Mode. This command may have to be issued multiple times. If the
refresh spe-standby command successfully completes five times without
the Standby SPE becoming labeled "standby" on the status system form,
wait 20 minutes. This does not include cases where the command
completes with the terminal message line errors "Refresh not successful;
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt
Standby SPE while entering maintenance mode; please try later." Issue the
refresh spe-standby command once more. If the Standby SPE is not
labeled "standby" on the status system form after this attempt, use the
busyout spe-standby and release spe-standby command to put the
standby into standby mode.
12. Repeat the command.
13. Issue the test spe-standby long command.
2025 ABORT The Standby SPE Maintenance/Tape Processor successfully released the
Standby SPE processor, but the Standby SPE processor did not successfully
carry out the requested function. Either there is a problem with one or more
components that make up the Memory Shadowing Link such that Active SPE
Memory was not accurately shadowed to Standby SPE Memory OR there is a
problem with the Standby SPE Processor circuit pack or the Standby SPE
Memory circuit pack.
1. Check for both Active SPE and Standby SPE Common Shadow Circuit
errors and alarms. Refer to SHDW-CIR (Common Shadow Circuit) and
follow the procedures.
2. Check for Standby SPE Memory errors and alarms. Refer to MEM-BD
(Memory circuit pack) and follow the procedures.
3. Check for Standby SPE Processor errors and alarms. Refer to PROCR and
follow the procedures.
4. Check the Inter-Carrier Cable to see if the cable is loose or disconnected.
If so, follow the repair procedures for reconnecting the Inter-Carrier Cable
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’.
5. If all problems found in Steps 1, 2, 3, and 4 have now been repaired,
proceed with Step 10. If no problems were found in Steps 1, 2, 3, and 4,
proceed with Step 6.
Table 10-410. Test Result Error Codes Associated with the Standby SPEContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page