Maintenance Commands and Trouble-Clearing Aids
Page 8-274status data-module
8
status data-module
This command displays internal software state information for diagnosis. This
command can help locate facilities to which the data module is communicating.
Output
For the following output example, the command that was entered is “status
data-module 301".
0xC2 (0t194) Ring no answer
0xC8 (0t200) Hi and dry - no feedback detected
0xC9 (0t201) Cascade link administered wrong
0xCA (0t202) CPTR not available to detect failure
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout mis
extension
print
data module extension
Report prints if a printer is linked to
the SAT.
Examples:
status data-module 30000
status data-module 32770
status data-module 32770 print
init
inads
craft
cust
rcust
bcms
browse
none none
Table 8-6. Status AC - Failure Cause Values — Continued
Failure Cause
(hexadecimal) Description
Continued on next page
status data-module 301
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 301 Service State: out-of-service
Port/Channel Number: 01C1103 Maintenance Busy? no
CF Destination Ext:
Connected Ports: