Maintenance Object Repair Procedures
Page 10-957PI-LINK (Processor Interface Link)
10
b. The TN765 Processor Interface circuit pack detected an error on a
specific link via background maintenance. If the link is down, busyout and
then release the link. If this fails, check all connections. If the error
reappears consistently, see "Link Recovery" section.
c. Processor Interface software or firmware detected an error condition on
this link. Internal software should initiate the recovery for the link. If the link
is still down, see the "Link Recovery" section.
Aux values of concern; any others can be ignored.
d. Translation Error—check all administration for the link. Possibly the
destination DS1-BD or DIG-BD is not inserted. Busyout and then release
the link to restart it. This is not a Processor Interface hardware problem.
Aux values of concern; any others can be ignored.
e. This error occurs when the Processor Interface link fails to be established.
Check all connections and administration. This could also occur as a
result of another error, the failure of Test #182, for example. If the other
error on the link can be cleared, then this error may also clear. See the
"Link Recovery" section
0 Processor Interface circuit pack indicates that the ISDN-PRI link is
down.
1 An internal software audit indicates that this link has been in
overload for at least 20 seconds and is hung.
2 No internal software buffers are available to process a link
transition (that is, down to up, or up to down). The transition is lost.
17 The allocation of a new software write buffer to the Processor
Interface circuit pack failed.
2 Link translation error. If the communication-processor link
form indicates this link’s destination is a tac+extension,
then bring up the dial plan form. If an extension exists with
the same first digit as the tac, then this PI link will not
establish. To alleviate this problem, either remove the
extension on the dial plan form, or change the destination
field on the communication-processor link form to use a
UDP extension to dial the far-end.
8 Port not administered in software.