Page 8-296status signaling-group
8
Field descriptions
Group ID: Numerical ID of the signaling group (1-8)
Type: facility associated signaling: all members are on a single
DS-1 facility. Facility associated signaling groups support only the
simplex D-channel configuration.
non-facility associated signaling: members can be carried
by multiple DS-1 facilities.
The DS-1 facility is identified across the ISDN-PRI using an explicit
facility identifier. In a simplex configuration one D-channel is used to
signal for B-channel members, while in a duplex configuration two
D-channels are used to signal for B-channel members (one channel is
active and the other is used as a backup to the active channel).
Group State: in-service: one of the D-channels signaling for the group is in
service
out-of-service: neither D-channel in the group is in service
NOTE:
If there is no D-channel backup and the primary D-channel is
out-of-service, then the signaling group is in an out-of-service
state.
Link: Link transporting the D-channel
Port: Address of the port transporting either the primary or secondary
D-channel
status signaling-group 1 Page 1 of 1 SPE A
STATUS SIGNALING-GROUP
Group ID: 1
Type: facility associated signaling
Group State: in-service
Primary D-Channel
Link: 1 Port: 01C1924 Level 3 State: in-service
Secondary D-Channel
Link: Port: Level 3 State: