DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1007PKT-CTRL (Packet Control Circuit Pack)
10
2102 FAIL As the Packet Control circuit pack firmware was being downloaded from
system tape, a block of data could not be read from the tape. This indicates
a problem with the tape unit, and not with the Packet Control circuit pack.
1. Test the TAPE with the long option and with a repeat option of 3. If any of
the tests fail, or if there are any tape alarms, refer to the TAPE
Maintenance documentation and follow the recommended repair
procedures. If a tape problem is detected and then fixed, then retry the
reset command.
2. If no tape problem was detected in the previous step, then there may be
a problem with the area on the tape where the Packet Control circuit
pack firmware resides. Replace the tape cartridge and then retry the
reset command.
2500 FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The reset command passed and the Packet Control circuit pack is
operational. If the Packet Control circuit pack was busied-out, it needs to be
released (via the release packet-control C command) before it can be
considered in service.
Table 10-344. TEST #586 Packet Control Reset Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page