Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-366test modem-pool
8
Defaults
The cabinet default is always 1. For SPE simplex systems, the default carrier is
the “a” carrier; for SPE duplex systems, there is no default carrier. The defaults
for the remaining parameters are short with a repeat of 1.
Output
The following example show the output for the test memory 1b command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
test modem-pool
This command performs hardware diagnostic tests on the specified modem pool
group or an individual member of a specified group (Combined or Integrated). A
Combined modem-pool group consists of pairs of Analog and Digital Line ports.
One pair of Analog and Digital Line ports used for modem-pooling is called a
conversion resource. An Integrated group consists of modem-pool circuit packs,
each containing two conversion resources. Therefore, when a member number is
specified for a Combined modem-pool group, one conversion resource is tested,
and when a member number is specified for an Integrated modem-pool group,
two conversion resources are tested.
Port The port address (cabinet-carrier)
Maintenance
Name
The name of maintenance object being tested is MEMORY.
Alt. Name Not applicable.
Test No. The test being executed
Result The result of the test: Pass, Abort, or Fail
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test memory 1b
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B MEM-BD 87 PASS
01B MEM-BD 631 PASS