Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1250TAPE (Tape Unit) [G3iV1.1-286]
10
9026 Hardware error detected. 1. Do the steps below following the directions
in the ‘‘
Tape Maintenance and Repair
Procedures’’ section.
2. Issue the test tape long commnd.dispatch
with tape unit.
3. If the test fails, make sure tape is fully
inserted.
4. If the test continues to fail, clean the tape
head.
Use original tape
and retest.
5. If the test still fails, swap tape unit,
use
original tape
and retest.
NOTE:
It is very important that hardware
problems are resolved
before
using
backup tape.
6. If fails again, swap tape and restest.
7. If the problem still exists, escalate the
problem.
9027 The test failed because the
software could not access the
tape hardware.
9030 Internal system error. 1. Follow the steps provided in the ‘‘
Tape
Maintenance and Repair Procedures’’
section.
2. If problem still exists then escalate.
9032 Inability to read a significant
portion of the scratch area on
the tape.
1. Follow the steps provided in the ‘‘
Tape
Maintenance and Repair Procedures’’
section.
2. If problem still exists then escalate.
9033 Inability to write a significant
portion of the scratch area on
the tape.
1. Follow the steps provided in the ‘‘
Tape
Maintenance and Repair Procedures’’
section.
2. If problem still exists then escalate.
Table 10-433. Table A: Tape Unit Aux Data Table — Continued
Aux Data/
Error Codes Explanation Strategy
Continued on next page