Maintenance Object Repair Procedures
Page 10-158BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The
aux data field contains one of the following values:
blank - this indicates that the Level 1 Status Inquiry failed.
32773 - this is a message from the BRI-LINE circuit pack indicating
Level 1 has been deactivated.
Refer to the repair procedures for Test #621.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, replace or
reinsert the circuit pack.
c. This error occurs when the EPF Status Inquiry fails due to an overcurrent
condition or when the BRI-LINE circuit pack detects that the EPF is in an
over current condition. The aux data field contains one of the following
values:
blank - this indicates that the EPF Status Inquiry failed due to an
overcurrent condition.
40988 - this indicates that the BRI-LINE circuit pack has detected
an overcurrent condition and has turned the EPF off.
Execute the Short Test Sequence and see the repair procedures for Test
#622.
d. This error indicates that the circuit pack is having problems transmitting
data to the Packet Bus, thus affecting the conveyance of signaling
information over the D-channel. With Aux Data 46222, this error occurs
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description, and follow the recommended procedures.
2. Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used in
the set options command.
3845 (m) None
3846 (n) TEI None
3847 (o) 0 None
Table 10-55. ISDN-BRI Port Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PORT
ATTE-PT
On/
Off
Board
Test to Clear
Value
Continued on next page