Page 8-391test station
8
Field descriptions
test station
This command performs hardware diagnostic tests on an individual port circuit
assigned to that extension. The technician must specify the extension and a
translation is automatically done to the physical port location.
Port The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name Alternate means of identifying the maintenance object. This field
contains the extension when the object is a data module.
Test No Test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test spe-standby SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B SHDW-CIR 285 PASS
01B SHDW-CIR 284 PASS
01B SPE-SELECT 278 PASS
01B DUPINT 315 PASS
. . . .
. . . .
. . . .
Command Successfully Completed