Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1196SVC-SLOT (Service Slot)
10
SVC-SLOT (Service Slot)
The Service Slot maintenance object is used to detect when an invalid circuit
pack is inserted into a SERVICE slot. The SERVICE slot is the leftmost slot in the
J58890BB Port Carrier. It is identified as circuit pack slot location "00" in all
commands, field entries, and displays used by the system administrator and the
service technician.
This slot does not provide tip and ring connectivity to the wall field. Therefore,
only the following circuit pack types are allowed in the slot:
Call Classifier (TN744)
Integrated Announcement (TN750)
Maintenance/Test (TN771C)
Speech Synthesizer (TN725B)
Tone Detector (TN748C)
A MINOR alarm is generated against the Service Slot maintenance object when a
circuit pack of a type other than that included in the previous list is inserted into a
SERVICE slot.
The Service Slot maintenance object name is used instead of the maintenance
object name for the illegal circuit pack to prevent any attempt to assign a port to
an illegal circuit pack that is physically inserted into the SERVICE slot.
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error type indicates that a circuit pack type other than one of the
following types was inserted into slot 00 (SERVICE slot) of the J58890BB
port carrier.
Call Classifier (TN744)
Integrated Announcement (TN750)
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
SVC-SLOT MINOR none Service Slot
Service Slot Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
600 (a) None MINOR ON