DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-236CARD-MEM (Memory Card)
10
Table 10-81. TEST #694 Memory Card Translation Data Integrity Test
Error
Code
Test
Result Description/ Recommendation
2012
2106
2114
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2013
2100
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2108 ABORT The NETCON circuit pack is not a TN777B circuit pack.
1. Follow the Standard Repair Procedures for replacing the NETCON
circuit pack with the TN777B circuit pack.
2. Re-enter the test card-mem command.
2110 ABORT No memory card is inserted.
1. Insert a formatted memory card into the slot at the TN777B NETCON
circuit pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2111 ABORT Inserted memory card cannot be recognized.
1. Insert a new formatted memory card into the slot at the TN777B
NETCON circuit pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2112 ABORT Internal system error The inserted memory card is a "system-upgrade"
memory card.
1. Replace the inserted memory card with a user’s memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL A checksum error is detected in the translation file that is stored in the
inserted memory card.
1. Enter the save translation command, and verify that translations can
be successfully saved onto the memory card.
2. Rerun the test.
3. If the test fails again, replace the memory card, and repeat Steps 1
and 2.
PASS No checksum error is found in the translation file.
Continued on next page