DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1384TIE-TRK (Tie Trunk)
10
1000 ABORT System resources required to run this test are not available. The trunk may
be busy with a valid call. Use the display trunk xx to determine trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then
check the Error Log for Error Type 1025 (see Error Log table for
description of this error and required actions). The port may be locked
up. The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display trunk xx to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is in use,
the port is unavailable for certain tests. (Refer to the "Status Commands"
section in Chapter 8, ‘‘
Maintenance Commands and Trouble-Clearing
Aids’’ for a full description of all possible states.) You must wait until the
port is idle before retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, and the port is not in use, escalate the
problem.
1005 ABORT This test is not valid for this trunk translation. Must be a Type-1 standard
trunk for this test to run.
1. Check trunk configuration. If it is not a Type-1 standard trunk, this abort
message should be ignored.
1014 ABORT The test was aborted because the circuit pack has not been inserted into
the system.
1. Use the list configuration board command to make sure the circuit
pack is inserted in the carrier.
2. If the board is not inserted, make sure the circuit pack is inserted in the
carrier and fully seated.
3. If the test continues to fail, escalate problem.
Table 10-480. TEST #74 Tie Trunk EPF Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page