DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1442UDS1-BD (UDS1 Interface Circuit Pack)
10
1. Make sure all conditions for administration are met and that a
functioning UDS1 circuit pack is inserted in the correct slot, or
2. Completely remove the UDS1-BD from the system using the
following steps:
a. Remove any administered DS1 trunks, access endpoints or
PRI endpoints associated with the circuit pack from their
trunk groups.
b. Execute the remove ds1 PCSS and change circuit pack
PCSS commands.
If all the administration conditions are met for this circuit pack and the red
LED is still on, follow the instructions for LED Alarms with Error Type 1 in
Chapter 7, ‘‘
LED Interpretation’’.
b. The UDS1 Interface circuit pack has been busied out by a busyout board
PCSS command.
c. The UDS1-BD circuit pack is not completely administered. To be fully
administered, the UDS1 circuit pack must:
1. Have an entry in the circuit plan via the change circuit pack
command,
2. Be administered via the add ds1 PCSS command, and
3. Be physically inserted into the correct slot.
A DS1 (UDS1-BD and DS1-BD) differs from most circuit packs in that
inserting the circuit pack into the switch is not enough to make the board
usable. It must also be administered with the add ds1 command.
d. No Aux Data: A wrong circuit pack is inserted in the slot where this circuit
pack is logically administered. To resolve this problem, either remove the
wrong circuit pack and insert the logically administered circuit pack OR
use the change circuit-pack command to readminister this slot to match
the circuit pack inserted.
Aux Data 3: The 24/32-channel option jumper setting on the circuit pack
does not match the option set on the DS1 circuit pack administration form.
The circuit pack must be physically removed to see the setting of the
jumper.
e. This error is associated with the Common Port Circuit Pack Maintenance
Test. Refer to XXX-BD (Common Port Circuit Pack) Maintenance
documentation for details.
f. The UDS1 Interface circuit pack has detected a transient hardware
problem. The value in the Aux Data field indicates the type of hardware
problem.
4352 External RAM failure
4353 Internal RAM failure
4355 Internal ROM failure