Maintenance Object Repair Procedures
Page 10-868M/T-ANL (Maintenance/Test Analog Port)
10
Table 10-291. TEST #9 NPE Cross Talk Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may
be in use on a valid ATMS trunk test call.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out of service due
to TDM-BUS errors. Refer to TDM-BUS Maintenance documentation to
diagnose any active TDM-BUS errors. A system is considered under heavy
traffic when the Call Processing Occupancy is greater than 50% or when
the System Management and the Call Processing Occupancies together
exceed 65%. To view the system occupancy measurements enter the
command status system health on the system technician terminal.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the test at 1 minute intervals a
maximum of 3 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a valid ATMS test call.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort and the port is not in use on a valid ATMS
Test Call, escalate the problem. To determine whether the port is in
use by an ATMS Test Call enter status station ext where ext is the
assigned ATMS station number.
Continued on next page