Maintenance Object Repair Procedures
Page 10-1170STBY-SPE (Standby SPE)
10
check for STBY-SPE errors" or "Cannot interrupt Standby SPE while
entering maintenance mode; please try later." Issue the refresh
spe-standby command once more. If the Standby SPE is not
labeled "standby" on the status system form after this attempt, use
the busyout spe-standby and release spe-standby command to
put the standby into standby mode.
2. Repeat the command.
3. Issue the test spe-standby long command.
Unable to interchange because the active SPE is locked active
An SPE interchange cannot be performed when the active SPE is locked
via the SPE select switches. Move the select switches back to the auto
position and retry the reset system interchange command.
Unable to interchange because the standby SPE is busied out
An SPE interchange can not be performed when the standby SPE is
busied out. Release the standby SPE by entering the release
spe-standby command and retry the command.
Unable to interchange due to alarms on the standby SPE; Use the
‘health-override’ option
When components in the standby SPE complex are alarmed, and if these
Standby alarms are more severe than the alarms in the active SPE
complex, the reset system-interchange command returns this message.
Using the reset system-interchange health-override command forces
the interchange. See the Reset System command page for more details.