DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1211SW-CTL (Switch Control)
10
2013
32511
ABORT Could not allocate the system resources to run for this test.
2012
32513
32514
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to “Standby SPE” for a description of these error codes.
32515 FAIL This failure indicates that communications with the Maintenance circuit
pack in the EPN is probably not possible. The EPN management terminal
may not be usable.
1. Run the Long Test Sequence several times to make sure the error is
occurring consistently. Remember the Long Test Sequence is
destructive. Placing and receiving calls is affected for several
seconds.
2. Replace the Netcon circuit pack.
3. The procedure for replacing the Netcon circuit pack is described in
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’. The procedure for
doing the same in systems without High or Critical Reliability is
described in Chapter 5, ‘‘
Routine Maintenance Procedures’’.
PASS The EPN Maintenance circuit pack interface between the processor and the
Switch Control is working correctly.
Table 10-419. TEST #325 Switch Control Destructive EPN
Maintenance Board Interface Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page