Maintenance Commands and Trouble-Clearing Aids
Page 8-80display system-parameters maintenance
8
Scheduled Maintenance
A series of maintenance tests and operations runs automatically every day
according to the schedule and settings specified in the following fields.
CPE Alarm Activation
Level
Indicates the minimum level (Major, Minor or Warning) at which
the Customer-Provided Equipment (CPE) alarm is activated. If
the level is none, the CPE does is not activated for any alarm.
(none)
NOTE:
The CPE alarm is always activated when the switch goes
into Emergency Transfer, regardless of the CPE Alarm
Activation Level setting.
Packet Bus Activated
Enables the system Packet Bus.
If this field read yes, then maintenance software assumes that
there is a Packet Control circuit pack installed in the system.
The packet endpoints (for example, ASAI, and/or BRI) may be
administered, and maintenance testing runs on both the
Packet Control circuit pack and on the Packet Bus (This field
should read yes after a packet control circuit pack is
installed.). If a Packet Control circuit pack is not installed in the
system, then a major alarm is raised against the PKT-CTRL MO.
This field can only be changed from “yes'' to “no'' if there are
no packet endpoints administered, thus ensuring that there
can be no packet endpoints administered if the packet bus is
not activated.
This field should be set to “yes” after a Packet Control circuit
pack is installed.
If a Packet Control circuit pack is not installed, then this field
should be set to “no'' (the only exception is when setting up
translations for a system for which not all of the required
hardware is available). (no)
Customer Access to
INADS Port
Provides the capability to prohibit access to system
administration and maintenance interface, via the INADS port
when using customer login ID’s. This field can only be activated
by Lucent services through system-parameters maintenance
administration.(no)
Repeat Dial Interval
(MMS)
Indicates the number of minutes that the system must wait
before attempting another call origination to an OSS. This timer
is triggered by the lack of a far-end acknowledgment. (7)
Start Time
The hour and minute (24-hour notation) at which daily scheduled
maintenance begins. (22:00)