DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-121test interface
A
If the technician-entered cabinet and carrier is invalid for a PPN, the following message
will be displayed:
Invalid port-network specified
If the technician-entered carrier is not a valid carrier, the following message will be
displayed:
Invalid carrier specified
If the technician-entered carrier is not active, the following error message will be
entered:
Board invalid
If the specified carrier/position processor interface circuit pack is not inserted, but the
specified carrier is active, the following error message will be displayed:
No such MO’s lname/pname
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, then the
following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the following
message is displayed:
Standby SPE memory not refreshed;
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the SPE
select switches when this command is executed, then the following message is
displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is displayed:
Standby SPE busy with another task;
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the following
message is displayed:
Standby SPE not available;
for information use "status system 1"