DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-151monitor bcms
8
Maintenance/Test circuit packs). If the port can be administered manually, and it
is unassigned, the port is marked as faulty. The clear port command reactivates
the port. The list marked-ports command displays marked ports in a list format.
All marked port information is saved as part of translations.
monitor bcms
The monitor bcms command displays output for agents and splits and
summarizes the bcms condition. This on-line status report automatically updates
every 30 seconds (or by pressing the
Update key) until the command is canceled
by pressing the
Cancel key. Three display options are available: skill, split, and
system.
Qualifier Description
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
mark port
location
Physical location: PCSSpp
Examples:
mark port 1c0208
mark port 2a1001
init
inads
craft
none none
Action/Object Qualifier
Qualifier
Description Permissions Defaults
Feature
Interactions
monitor bcms
split
split number
system
system number
skill
skill number
see below init
inads
craft
cust
rcust
bcms
browse
none none
split
Specifies that the command display status information for a specified
split number (an ACD hunt group).
split number
The split’s identity to the switch and BCMS; an ACD hunt group
number (split number). This parameter is entered only when the "split"
parameter is entered.
system
This specifies that the command display split queue status as well as
cumulative split information for all the BCMS measured splits.
system
number
ACD hunt group numbers (split numbers) separated by spaces and/or
split number ranges separated by a hyphen ("-").
skill
This specifies that the command display status information for a
specified skill number.
skill number
The skill’s identity to the switch and BCMS; an ACD hunt group
number (skill number). This parameter is entered only when the "skill"
parameter is entered.