Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1382TIE-TRK (Tie Trunk)
10
1005 ABORT (Non-TN439 circuit packs only.) This test is not valid for this trunk
translation. For this test to run, a delay dial trunk (or, for non-TN497 circuit
packs, a wink-start trunk) must be in effect, and the trunk must be outgoing
or two-way. Also, for the TN2140 [G3iV2-386], the trunk must be
continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this
abort message should be ignored. (For the TN2140 [G3iV2-386],
disregard this abort on a trunk that is not continuous-seize-ack or
discontinuous-seize-ack.)
1018 ABORT Test disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk Group Form is
set to "n." To enable the test, issue the change trunk-group x
command where "x" equals the number of the trunk group to be
tested. Then change the entry in the "Maintenance Tests?" field on the
form to "y."
1040 ABORT (Non-TN497 circuit packs only.) This test is not performed for trunk ports
administered as access endpoints.
1. Verify this port is an access endpoint by using the display port
command.
2. If the port has been administered as an access endpoint, this test
should abort.
2000 ABORT Seizure message is not received back within 10 seconds.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
2100 ABORT Could not allocate the necessary system resources to run the test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
3 FAIL (TN439 circuit packs only.) No dial tone detected from the other end.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to fail, check the far-end PBX to ensure a
translation match at both ends.
3. Check the facility.
Table 10-479. Seizure Tests (#73, #747, #73) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page