Maintenance Object Repair Procedures
Page 10-259CARR-POW (Carrier Port Power Unit) for AC-Powered Systems
10
Table 10-88. TEST #127 Power Unit Query Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to ABORT with error code 2000, check for system
powering problems with the A carrier (PPN or EPN). Look for and
resolve all AC-POWER and CARR-POW alarms in a multicarrier
cabinet system or DC-POWER alarms in a single-carrier cabinet
system. Then, repeat the test.
3. If the test continues to ABORT with a 2000 error code, check for and
resolve all DUPINT (Duplication Interface) errors in a Duplicated
Option PPN, PR-MAINT (Maintenance/Tape Processor) errors in a
standard PPN, or MAINT (EPN Maintenance circuit pack) errors in an
EPN. Then, repeat the test.
4. If the test continues to ABORT with a 2000 error code, escalate the
problem.
2029 ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.