DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-301status system
8
Output
The following example shows the output for the status synchronization
command.
Field descriptions
status system
This command displays the status, mode, and operational attributes of the
SPE(s), TDM and Packet busses, tone-clock circuit pack(s), expansion interface
links (exp-links), and emergency transfer switch of single or all cabinets in the
system.
!
CAUTION:
The purpose of this command is to provide general information about the
cabinet status. This information may not display correctly when the cabinet
is in a transient period. In this case, wait for 1 minute and enter the
command again.
Stratum Level Synchronization stratum level (3 or 4)
Maintenance
Name:
Either TONE-BD, DS1-BD, or STRAT-3.
Physical
Location
Board location of the selected DS1 or tone-clock circuit pack
(cabinet-carrier-slot for a DS1; cabinet-carrier for a tone-clock)
Switching
Capability
Whether the on-line reference for synchronization can be switched
(Enabled or Disabled)
Excessive
Reference
Switching
High-level description of how many times the synchronization
reference has been switched. If excessive reference switching is
taking place (sync error 1793 is at threshold), this field displays
Yes; otherwise No displays.
status synchronization
SYNCHRONIZATION STATUS
Stratum Level:4
Maintenance Name: TONE-BD Physical Location: 01A
Switching Capability: Enabled
Excessive Reference Switching: No