DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-674HYB-LINE (Hybrid Line)
10
HYB-LINE (Hybrid Line)
Hybrid Line is the user-friendly name for Hybrid Line, which was previously used
to denote the Multifunction Analog Telephone. The Hybrid Line set is also known
as an SCS (Small Communications System).
The TN762B Hybrid Line circuit pack supports eight of these multifunction
analog telephone sets, as shown in the following figure. The Hybrid Line sets use
three pairs of wires: an analog voice pair, a transmit/receive pair, and a power
pair.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit
port number (for example, 01).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
Full Name of MO
HYB-LINE Minor test port PCSSpp l Hybrid Line
HYB-LINE Warning test port PCSSpp l Hybrid Line