Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-567DUPINT (Duplication Interface Circuit Pack)
10
done entirely on the Duplication Interface circuit pack. The test passes if the data
sent matches the data received. This test does not check the physical serial
channel that is printed on the backplane or carried by the ICC.
Duplication Interface Circuit Pack Status Query
Test (#315)
This test is used to detect the presence of Duplication Interface circuit packs A
and B. To determine the status of Duplication Interface circuit pack B, a query is
sent to the Duplication Interface circuit pack A. To determine the status of
Duplication Interface circuit pack A, a query is sent to the Maintenance/Tape
Processor on the active carrier. The response to either query indicates the status
of the handshake to the appropriate Duplication Interface circuit pack.
Table 10-194. TEST #280 Inter-Duplication Interface Circuit Pack Loop Back Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The tested UART on the Duplication Interface circuit pack is defective.
1. Replace the Duplication Interface circuit pack.
2. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack B has failed to reply to handshaking
either from Duplication Interface circuit pack A.
1. Refer to NO BOARD description for the Duplication Interface Circuit
Pack Status Query Test (#315).
PASS The Inter-DUPINT UART on the tested Duplication Interface circuit pack is
good.
Continued on next page