DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-379test pri-endpoint
8
Output
The following example is the output for the test port command and assumes that
the port in cabinet 1, carrier c, slot 7, circuit 1 is an analog port. The responses
display on a test-by-test basis with one line of data for each test result.
Field descriptions
test pri-endpoint
This command performs hardware diagnostic tests on all port circuits
(B-channels) that are associated with the PRI endpoint extension.
The test pri-endpoint command performs hardware diagnostic tests on all port
circuits (B-channels) that are associated with the specified PRI endpoint.
Port Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object.
Alt. Name The alternate means of identifying the maintenance object.
If the Object is a The field contains
station extension
trunk xxx/yyy (xxx = trunk group number and yyy =
member number)
private CO line P/xxx (xxx = private CO line group number)
Test No Test being executed.
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test port 01c0701 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS
Command Successfully Completed