Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1036PR-MAINT (Maintenance Processor [TN790 RISC Systems])
10
Notes:
a. The MTP Reset Test (#101) has failed.
b. The MTP Sanity Handshake Test (#106) has failed.
c. The MTP Analog Loop Around Test (#103) has failed.
d. The MTP Dual Port Ram Test (#104) has failed. An error of 769 with an aux
data of 5 indicates a hardware problem and testing cannot clear it.
Replace the circuit pack.
e. The MTP Outpulse Relay Test (#102) has failed.
f. The MTP SAT Loop Around Test (#228) has failed.
g. The MTP Aux Loop Around Test (#229) has failed.
h. The External Modem Present Test (#230) has failed.
NOTE:
Refer to the FAIL section of each test that fails for further instructions.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the
MTP Reset Test,
for example, you may also clear
errors generated from other tests in the testing sequence. The following table is
for the TN790 [RISC] System.
1. The MTP Reset Test (#101) logs you off. The MTP Dual Port Ram Test (#104) can also log you off.
Manually repeat the command with the ‘‘long’’ option for the designated number of times when
testing from the PPN SAT.
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
1537(f) Any MTP SAT Loop Around Test
(#228)
MIN ON test processor a/b r 3
1793(g) Any MTP Aux Loop Around Test
(#229)
MIN ON test processor a/b r 3
2049(h) Any External Modem Present
Test (#230)
MIN OFF test processor a/b r 2
Table 10-353. PR-MAINT Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
Continued on next page