DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-62release spe-standby
A
release spe-standby
Help Messages
If the system technician presses HELP after entering "release spe-standby" the following
message will be displayed:
Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
release station
Help Messages
If the system technician presses HELP after entering "release station," the following
message will be displayed:
Enter extension for an assigned station
Error Messages
If the format of the extension is incorrect, the following error message will be displayed:
Extension invalid
If the specified extension is not administered, then the following message will be
displayed:
Extension not assigned
If the specified extension does not belong to a station or attendant console, the following
message will be displayed:
Extension exists but assigned to a different object
If the station port resides on an EPN that is unavailable, the following message will be
displayed:
EPN is not available
If the station port resides on a board that is not inserted in the system, the following
message will be displayed:
Board not assigned