Maintenance Object Repair Procedures
Page 10-1379TIE-TRK (Tie Trunk)
10
Audit Update Test (#36)
This test sends updates of the Tie Trunk port translation for all ports on the circuit
pack that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the board. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data for non-TN439 and non-TN497 circuit packs includes
the following: Immediate, automatic, wink-start or delay dial trunk, rotary or DTMF
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments,
and DMTF time slot. (Continuous-seize-ack is also included for the TN2140
[G3iV2-386] circuit pack.) The port translation data for the TN439 circuit pack
includes the following: Immediate or wink-start trunk, rotary or DTMF
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments,
and DMTF time slot.
PASS Tie trunk Loop Around and Conference Test is successful. This port is
functioning properly.
1. If users are reporting troubles, examine loop connections to the port.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 10-477. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page