DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-998PKT-CTRL (Packet Control Circuit Pack)
10
Table 10-341. TEST #583 Packet Control Error Counter Read/Clear Test
Error
Code
Test
Result Description/ Recommendation
1029
2011
2012
2013
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1141 FAIL The Packet Control circuit pack is not operational. A busied-out Packet
Control circuit pack can still be operational.
1. Determine if the Packet Control circuit pack has an active major alarm
(via the display alarm command). If it does, follow the recommended
repair procedures to retire the alarm. Once the alarm is retired, the
original command can be retried.
2. If the Packet Control circuit pack does not have an active major alarm,
wait one minute and retry the original command. If the Error Code
1141 is again observed, go to the next step.
3. If the Packet Control circuit pack is on the active SPE and is not
currently busied-out, issue the busyout packet-control C command.
Issue the reset packet-control C command. If the reset command
fails, follow the recommended repair procedures for Test #586. If the
reset command passes, issue the release packet-control C
command (if the Packet Control circuit pack is on the active SPE), and
reissue the original command.