Maintenance Object Repair Procedures
Page 10-817MET-LINE (MET Line)
10
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the
station extension, attendant number, or trunk group/member number of
the port. Use the status station, status attendant, or status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 8,
‘‘Maintenance Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the port is idle
before retesting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
Table 10-274. TEST #57 MET Circuit and Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page