DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-287status link
8
Field descriptions
Link Number
Processor Interface link number (1-8).
Link Status
Valid link states:
—in-service
— PI link is up and providing service.
— maintenance busy
— system technician busies out the PI link.
— disconnected
— PI link is down. Check the Hardware Error Log for
more information.
Destination
Character string identifying the link destination type.
Valid types are: “ISDN-LNK”, “ISDN-TRK”, “TIE-DS1”,
“PDMODULE”, “TDMODULE”, and “EIA LINK”.
status link 1
PI LINK STATUS
Link Number: 1 Destination: TDMODULE Port: 1C0303
Link Status: in-service Dest Status: in-service/active Ext: 4002
ERROR COUNTERS
Hardware Device Check (receive): 0 Level 2 I-frames retransmitted: 0
Hardware Device Check (transmit): 0 Level 2 Reset (SABM): 3
Far-End MOOS Count: 0 Invalid Frame Count: 0
Far-End FRMR: 0 Far-End SABM(E)/DM: 0
Far-End DISC: 0 Protocol Error Detected: 0
Timeout: 0 Local Busy Out: 0
oftware Initiated Link Down: 0 Firmware Initiated Link Down: 0
LOCAL/REMOTE PROCESSOR CHANNELS
1/