Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-312status tsc-administered
8
Field descriptions
status tsc-administered
The status tsc-administered command displays the operational status of TSC’s
administered for an administered signaling group. The status represents the
state of the TSC according to switched services.
Member Trunk group number/group member number (1-99/1-99).
Port Port location (cabinet-carrier-slot-circuit)
Service State Trunk service state:
in-service/active, in-service/idle, out-of-service-NE, out-of-service-FE,
maint-NE/active, maint-FE/active, maint-NE/idle, and maint-FE/idle.
NE (Near End; switch) and FE (Far End; PRI terminal adapter or any
device that terminates the D-channel signaling) refer to which “end”
of the B-channel has placed the facility in the current state.
Mtce Busy Whether any maintenance testing is being performed
Connected
Ports
Port locations (cabinet-carrier-slot-circuit) connected to the trunk
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status tsc-
administered
signaling
group
#/tsc
index
print
Administered signaling group
number
Number associated with each
TSC in a signaling group
Report sent to printer
Examples:
status tsc-administered 1
status tsc-administered 1/1
status tsc-administered 1/2 print
init
inads
craft
none none
status trunk 78
TRUNK GROUP STATUS
Member Port Service State Mtce Connected Ports
Busy
078/001 01C1505 in-service/idle no
078/002 01C1506 in-service/idle no