DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-448DIG-LINE (Digital Line)
10
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config
command (the display shows a t for the port).
2. If either list config or display port indicate that the port is
not
a TTI
port, escalate the problem. If both commands indicate that the port is
a TTI port, the abort is correct, and no action is necessary.
2000 ABORT Response to the test request was not received within the allowable time
period.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, escalate the problem.
PASS Station Audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 10-147. TEST #17 Station (Digital) Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page