DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1002PKT-CTRL (Packet Control Circuit Pack)
10
Table 10-343. TEST #585 Packet Control Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1029
2011
2012
2013
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1139 ABORT The Packet Bus is alarmed.
1. Try to retire the alarm associated with the Packet Bus. Refer to the Alarm
Log via the display alarm command.
2. Retry the command when the alarm associated with the Packet Bus
circuit pack is retired.
1141 ABORT The Packet Control circuit pack is not operational.
NOTE:
A busied-out Packet Control circuit pack can be operational.
1. Determine if the Packet Control circuit pack has an active major alarm
(via the display alarm command). If it does, follow the recommended
repair procedures to retire the alarm. Once the alarm is retired, the
original command can be retried.
2. If the Packet Control circuit pack does not have an active major alarm,
wait one minute and retry the original command. If the Error Code 1141 is
again observed, go to the next step.
3. If the Packet Control circuit pack is not currently busied-out and is on the
active SPE, issue the busyout packet-control C command. Issue the
reset packet-control C command. If the reset command fails, follow the
recommended repair procedures for Test #586. If the reset command
passes, issue the release packet-control C command (if the Packet
Control circuit pack is on the active SPE), and then reissue the original
command.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.