DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Routine Maintenance Procedures
Page 5-31Software Upgrade
5
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Shutdown
from the
Reset System
menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the control cabinet to be
upgraded, shut down the AUDIX assembly and allow the disk to
completely spin down.
!
WARNING:
Neglecting to shut down AUDIX before powering down the system
cabinet where it resides can damage the AUDIX disk.
2. Manually Power Down AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to
shut down the DEFINITY AUDIX System prior to powering down the
system.
a. Using a pointed object, such as a paper clip or pen (do not use a
pencil), press the Boot/shutdown button. The button is located at
the top right portion of the front panel.
b. Hold the boot/Shutdown button in until the LCD display flashes the
message MSHUT.
c. Release the Boot/Shutdown button.
NOTE:
The DEFINITY AUDIX System takes about five minutes to shut
down. The “heartbeat” indication on the display continues to
flash.
3. Unseat the AUDIX assembly from its backplane connectors in the carrier.
Power Down Basic Control Cabinet
!
CAUTION:
Do not power down the entire system. This defeats the purpose of high or
critical reliability configurations.
!
CAUTION:
Powering down the control cabinet causes important system data, such as
BCMS data, records of queued ACD calls, Automatic Wakeup request, and
Do Not Disturb requests to be lost. Refer to DEFINITY Enterprise
Communications Server Release 5.4 Maintenance for R5vs/si for
information about preparing the system for a power down.