Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1105S-SYN-PT (Speech Synthesis Port)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has
occurred. Refer to Test #168 for repair procedures.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Speech Synthesis Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1(a) 17672 None
18 0 busyout port PCSSpp WARNING OFF release port PCsspp
130(b) None WARNING ON test port PCSSpp sh
257 Speech Synthesis
PSS Handshake Test
(#168)
MAJOR ON test port PCSSpp sh r 2
513 17922 Speech Synthesis
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
769 17664 Speech Synthesis
DTMF Receiver
Inquiry Test (#164)
MINOR ON test port PCSSpp sh r 2
1025 17670 Speech Synthesis
SSD Inquiry Test
(#167)
MINOR ON test port PCSSpp sh r 2
1281 Speech Synthesis
DSP Tone Test (#165)
MINOR ON test port PCSSpp sh r 2
1537 Speech Synthesis
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
1793 Speech Synthesis
DTMF Receiver Test
(#163)
MINOR ON test port PCSSpp l r 2
2049(c) Conference Circuit
Test (#7)
MINOR ON test port PCSSpp l r 2
2305 NPE Crosstalk Test
(#6)
MINOR ON test port PCSSpp l r 2
3840(d) Any None