Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-47display alarms
8
The fields on the options screen are described below:
Output
After you complete the options screen, the system displays a 1- or 2-page Alarm
Report. To toggle between the pages and to exit the report, use the keys
described below:
For 513 and 715 terminals, use F8 for NEXT PAGE and PREV PAGE commands
For all other terminals, use F7 for NEXT PAGE and PREV PAGE commands
Use Esc for the CANCEL command
ALARM TYPES Enter y (yes) or n (no) in any of the 5 alarm type fields
Interval Enter one of the codes below:
m = last month
h = last hour
d = last day
w
= last week
a = all (default)
From Month/day/year (example: 01/01/97); if the From date is blank, the
report contains all the active alarms for the month
prior
to the current
date.
To Month/day/year (example: 01/15/97); if the To date is not entered,
the report contains all the active alarms starting with the From date
to the current date.
Cabinet Administered cabinet number (1-3)
Port Network 1-3
Board
Number:
Board address (PCSS); example: 01A20
Port Port address (PCSSpp); example: 01A2031
Category Object code for the equipment category. Press
HELP in this field to
view a list of the object codes.
Extension Extension number (per dial-plan)
Trunk Enter a group number or a group and member number:
Enter
only
the group number (01-99) to display
all
members in
the group. Example: 01/__
Enter
both
the group number (01-99) and member number
(01-99) to display a
specific
member in a group.Example: 01/99