DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-30ADX16D-P (16-Port AUDIX Digital Port)
10
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link. This is an off-board problem
that is detected by the port circuit. If this problem exists, replace the
circuit pack (see caution at the beginning of this section). Once the
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the
voice port. When an error with the link is detected, an on-board counter is
incremented. Also see Note a, above.
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Release the port with the release
port PCSSpp command.
e. The circuit pack is administered but not physically installed. The alarm will
clear when a circuit pack is inserted.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms may be downgraded to Warning alarms based on the values used in the set options
command.
Table 10-12. DEFINITY AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to 20 None WARNING OFF
15(c) Any None
18(d) 0 busyout port PCSSpp WARNING OFF release port PCSSpp
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port PCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice and Control
Local Loop TEST
(#13)
MIN/ WRN
2
ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MIN/ WRN
2
ON test port PCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None