DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-453DIOD-DS1 (DS1 DIOD Trunk)
10
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57392 indicates no external release on PBX disconnect.
Escalate the problem.
f. Error Type 513—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57393 indicates belated external release on PBX disconnect.
Escalate the problem.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:
—57484, fault is
detected on tip/ring. Escalate the error.
h. The DS1Interface circuit pack detects a hardware fault, and the Aux Data
field contains the following error type: 51200, port is unavailable. Run the
Dial Tone Test (#314) and follow procedures.
i. Error Type 1793—DS1 Interface circuit pack is out-of-service. Look for
UDS1-BD errors in the Hardware Error Log if the port is on a TN464 UDS1
board. Refer to the UDS1-BD (DS1 Trunk Circuit Pack) Maintenance
documentation for details
j. Error Type 2049—With the following Aux Data:
Aux Data 57473—Rotary dial rate below 8 pulses per second.
Aux Data 57474—Rotary dial rate above 12 pulses per second.
Aux Data 57475—Rotary Dial interdigit time is too short.
The DS1 interface circuit pack detects a hardware error on the DS1 DIOD
trunk. The trunk can not communicate with the far-end because it is
unable to interpret digits sent from the far-end switch. Check with the
far-end switch or Operating Company for proper trunk connection.
k. Error Type 2305—Recorder message, trunk could not be seized (Aux Data
50944). Run Test #314 and follow the outlined procedures.
l. Error Type 2562—Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
m. Error Type 2817—Glare error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error is the result of a simultaneous seizure of a two-way trunk
from both the near-end and the far-end. Attempt to place the call again. If
the error persists, execute the Dial Tone Seizure Test (#314) and follow
those procedures.