DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-69reset maintenance
A
If the standby SPE is not available when this command is executed, then the following
message is displayed:
Standby SPE not available;
for information use "status system 1"
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
reset maintenance
Help Messages
If the system technician presses HELP after entering "reset maintenance" the following
message will be displayed:
Enter cabinet([0]2-[0]3);[carrier(A)]
Error Messages
If the cabinet entered is non numeric or not within a valid range, the following message
will be displayed:
Cabinet number out of range; Enter 2 - 3
If the length of the user entered parameter exceeds three (3), or is in any other way
invalid, the following message will be displayed:
Entry invalid
If the command entered is in conflict with another currently executing command, then a
message displays showing the login ID of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict