DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1565XXX-BD (Common Port Circuit Pack)
10
1018 ABORT There are not any translated ports on the circuit pack, or if there are ports,
then none are administered to have "neon."
1. Verify that there are ports administered on the circuit pack. If no ports
are administered, no further action is required.
2. Make sure a TN755 or TN752 power unit circuit pack is installed.
3. Verify that you have neon sets connected (AT&T sets that may be
neon sets are 500 and 2500 series, also some non-AT&T may also be
neon sets). If no neon sets are connected to the circuit pack, the test
continues to abort, but no further action is required.
4. If there are no neon sets connected to the circuit pack, at least one
port needs to be translated with neon. To check if a port is translated
with neon, use the display port PCSSpp command to determine the
station extension of any station on this circuit pack. Use the display
station <extension> to determine if the port is administered with
neon. The field "Message Waiting Indicator:" must be set to "neon" for
at least one of the administered ports. If this field is not administered to
"neon" the test continues to abort. This is acceptable because not all
stations have neon lamps on their analog terminals. If none of the
terminals have neon lamps, the the test continues to abort, but no
further action is required.
1018 ABORT
(cont’d.)
5. Retry the command again.
6. If the test continues to abort with neon translated ports, escalate the
problem.
7. Retry the command at one-minute intervals a maximum of five times.
8. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for this test on other circuit packs as
well, then the ringing generator may be defective or is not wired
correctly (see errors for RING-GEN). If it doesn’t occur on port test 48
for ANL-16-L, all four ring phases are in use.
9. If the test to continues to abort, escalate the problem.
10. Retry the command again.
11. If the test continues to abort with neon translated ports, escalate the
problem.
Table 10-530. TEST #220 Neon Test — Continued
Error
Code
Test
Result Description/ Recommendation