DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-20ADX8D-PT (AUDIX Digital Port)
10
ADX8D-PT (AUDIX Digital Port)
The ADX8D-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack (sometimes called Embedded AUDIX) operating in
digital-port (DP) mode. The maintenance strategy for ports on the TN566
operating in control-link mode is described in ADX16A-PT.
The tests described in this section apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in
DEFINITY
AUDIX System Maintenance
, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction
Board (MFB) and the TN2169 Alarm Board (ALB). Because of its size this
combination occupies 5 slots, but only 1 slot is functional as far as the switch is
concerned. The other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots
(or ADXDP-RS/ADX8D-RS.)
In DP mode the TN566 pack supports up to 8 voice ports, each with a primary
information channel and a secondary information channel. Ports are
administered in increments of two. When a call to a station with an AUDIX login is
not answered, AUDIX answers the call using one of the available voice ports.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow
instructions on the TN566/TN2169 faceplate:
■
Remove DEFINITY AUDIX circuit packs
■
Cycle power to a carrier containing DEFINITY AUDIX circuit packs
■
Remove power to a carrier containing DEFINITY AUDIX circuit packs
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier
designation (A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack
resides (01 to 21).
pp
is the two digit port number (01, 02, ...).
MO Name (in
Alarm Log)
Alarm
Level Initial Command To Run
1
Full Name of MO
ADX8D-PT MINOR test port PCSSpp l AUDIX Digital Port
ADX8D-PT WARNING test port PCSSpp sh AUDIX Digital Port