Maintenance Object Repair Procedures
Page 10-1099RING-GEN (Analog Ring Generator)
10
Analog Ring Generator Initialization Test (#117)
The TN768, or TN780 will report an error to the system software if the ringing
voltage falls to low (only if system software has made a request to the TN768, or
TN780 to monitor the voltage). The Analog Ring Generator Initialization Test
sends a request to the TN768, or TN780. If there are redundant tone/clock circuit
packs in the port network, then the request is sent only to the active tone/clock.
Analog Ring Generator Query Test (#118)
This test requests the Active Tone-Clock circuit pack to check the ringing
voltage. The tone/clock circuit pack replies with PASS if the ringing voltage is
adequate to ring the analog phones. If not, the active tone/clock circuit pack
replies with a FAIL. The Analog Ring Generator Query Test then reports the
result.
Table 10-390. TEST #117 Analog Ring Generator Initialization Test
Error
Code
Test
Result Description/ Recommendation
1
1000
1001
1003
1115
2012
2100
ABORT The system software is unable to determine the active tone/clock circuit
pack, unable to allocated the resources necessary to run the test, or unable
to send a down link message.
1. Wait for the green LED on the active tone/clock to go out; use the status
port-network command to determine the active Tone/Clock circuit
pack.
2. Rerun the test. If the test aborts again, refer to TDM-CLK Maintenance
documentation.
2000 ABORT Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all other Tone/Clock
problems first.
2. Rerun the test.
1005 ABORT The tone/clock is unable to read the analog ringing voltage level when the
tone/clock is in the Processor Interface slot. This test is not available for the
Processor Port Network in this configuration.
PASS The active Tone/Clock has successfully been enabled to monitor the ringing
voltage level.
Continued on next page