DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-920PDMODULE, TDMODULE (Data Module)
10
Data Module Audits Test (#17)
This is a series of six tests that are classified as hardware audits. The processor
sends messages to the on-board microprocessor to perform the following tests.
[G1] The audits run only if the station is in-service.
Switchhook Inquiry — This is an update of the processor’s software
records based on the on-hook/off-hook status of the data module.
Bad Scan Inquiry — A message is sent uplink that contains a count
generated by certain events relating to the digital loop’s (link) conditions.
This could be an indication of communication problems between the
processor and digital port circuit pack.
7 FAIL Conference test failed on the primary information channel. In some
cases, user may not notice disruption in service. In extreme cases,
conferencing feature may not work at all.
14 FAIL The primary information channel is not transmitting properly. User
impact may range from noticing nothing to not being able to use this
port.
15 FAIL The control channel between the processor and Digital Line circuit
pack is not transmitting properly. This can cause a wide range of
effects. The user may notice nothing or the port may be totally
unusable. This could also disrupt other users.
1. Run circuit pack tests to check the Tone Generator and the Tone
Detector circuit packs using the test board UUCSS short
command.
2. Resolve any problems that are detected on the Tone Generator
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the Digital Line
circuit pack.
16 FAIL The secondary information is not transmitting properly. This can cause
a wide range of effects. The user may notice nothing or the port may be
totally unusable.
1. To be sure that this is not an intermittent problem, repeat this test
up to a maximum of 10 times to make sure it continues to pass.
2. If complaints still exist (poor data transmission), examine the data
module, connections, and wiring.
PASS Information and Control Channel Local Loop Test passed. All channels
are transmitting properly.
Table 10-308. TEST #13 Information and Control Channel Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation