Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-228CARD-MEM (Memory Card)
10
5. Once the alarm is resolved, enter the save translation command to store
the current system translations to the memory card.
6. If applicable, enter the save announcements command to store the
current announcements to the memory card.
Error Log Entries and Test to Clear Values
1. Run the Short Test sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-79. Mrmory Card Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test card-mem
1(a) Memory Card Insertion
Test (#695)
MINOR OFF test card-mem
257(b) Memory Card Format and
Read Test (#696)
MINOR OFF test card-mem
513(c) Any Memory Card Match and
Read Test (#697)
WARNING OFF test card-mem
769(d) Memory Card
Write-Protected Test
(#698)
WARNING OFF test card-mem
1025(e) 104
105
106
107
108
Memory Card Dir.
Recovery Test (#699)
MINOR OFF test card-mem
1281(f) Any Memory Card Translation
Data Integrity Test (#694)
MINOR OFF test card-mem long
1537(g) 104
105
106
107
108
Memory Card
Erase/Write/Read Test
(#693)
MINOR OFF test card-mem long
3329(h) any None MINOR/
MAJOR
OFF
3841(i) Any Save Translation MINOR OFF save translation
3843(j) Any Save Translation MINOR OFF save translation
Continued on next page