Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-880M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Table 10-296. TEST #9 NPE Cross Talk Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port
may be in use on a valid ISDN-PRI test call. Use the list isdn-testcall
command to determine if the port is in use (if the port is listed in the M/T
Port column). If it is in use, either wait for the test call to complete (as
indicated in the Start Time and Duration fields in the above display), or
abort the test call with the clear isdn-testcall tg/mem command, where
tg/mem is determined from the B-channel field of the above display.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out of service
due to TDM-BUS errors. Refer to TDM-BUS Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present or some
tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
Continued on next page