Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-459DIOD-DS1 (DS1 DIOD Trunk)
10
DS1 CO Dial Tone Seizure Test (#314)
DS1 CO Dial Tone Seizure Test checks the trunk’s signaling capability provided
by the DS1 Interface circuit pack. The maintenance software initiates the test by
sending a ‘‘seizure’’ message to the DS1 Interface circuit pack and expects an
‘‘active’’ reply from the DS1 interface circuit pack. If the ‘‘active’’ message is
received, then the test passes. If no message is received and the timer expires,
the test is aborted. If the DS1 Interface circuit pack sends a ‘‘reorder’’ message
back to maintenance software, then the test fails.
This test cannot be run on a trunk in any of the following conditions:
The trunk direction is administered as an incoming only trunk.
The trunk has been seized by a normal trunk call.
The trunk is administered with maintenance test disabled.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, escalate the problem.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test will not run but will return PASS. To verify
that the trunk is in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If
the trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
Table 10-151. TEST #36 Port Audit and Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page