DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-62display errors
8
The figure below is an example of an Hardware Error Report -- Active Alarms,
with the high-resolution qualifier in the command line.
When you enter the command display errors high-resolution, the system adds
the Seq Cnt (sequence count) column. The number in the column indicates the
order of errors logged within a second for the time stamps associated with the
first occurrence and the last occurrence of an error. Refer to the field description
above for more details.
Rt/Hr Rate per Hour - An approximation of the rate that this error
occurred in the last hour.If the number of errors exceeds 3 digits,
the system enters the number 256, which indicates that a larger
number of errors occurred, but could not be displayed correctly.
Al St Alarm Status - A character indicating the status of this MO in the
error and alarm logs. The allowed values are:
a
= Active alarm entry
r
= Resolved alarm entry
c
= Resolved alarm entry as a result of the long “clear” option
of the test command
s =
Resolved alarm entry as a result of a software requested
(non-demand) system restart
t
= Resolved alarm entry as a result of a technician requested
system restart
n
= Not alarmed.
Ac Active? - A y (yes) entry indicates the maintenance object is still
active. A n (no) entry indicates the object is no longer a problem.
display errors high-resolution Page 1 SPE A
HIGH RESOLUTION HARDWARE ERROR REPORT - ACTIVE ALARMS
Port Mtce Alt Err Aux First Seq Last Seq Err Al
Name Name Type Data Occur Cnt Occur Cnt Cnt St
01C0702 ANL-LINE 311 257 01/31/09:20:21 1 01/31/20:26:05 1 255 a
01C0701 ANL-LINE 1051 257 01/31/20:26:18 1 01/31/20:26:18 7 4 a
01C0703 ANL-LINE 1053 257 01/31/20:26:18 2 01/31/20:26:18 8 4 a
01A TDM-CLK 0 0 01/31/20:34:35 1 01/31/20:34:35 1 1 a
01C1505 CO-TRK 078/001 3329 57408 01/31/20:26:07 1 01/31/20:27:28 1 5 a
01C1505 CO-TRK 078/001 1537 01/31/20:26:52 1 01/31/20:28:41 1 5 a
02A0201 TONE-PT 0 01/31/20:34:28 1 01/31/20:34:28 1 1 a
PN 02B TDM-BUS 18 0 01/31/14:53:03 1 01/31/21:12:22 1 1 a
Command successfully completed