DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-135ASAI-PT
10
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The
aux data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the Packet Bus,
thus affecting the conveyance of signalling information over D-channel.
This error occurs when the Packet Bus transmit FIFO buffer overflows. This
condition probably indicates a hardware problem as well. The ASAI-PORT
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for
both on-board hardware problems and potential off-board Packet Bus
problems.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Major and Minor alarms may be downgraded to warning alarms based on the value used in the set
options command.
Table 10-47. ASAI-PT Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm Level
ASAI-PORT
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) (a) Level 1 Status
Inquiry (#621)
MAJ
2
OFF test port PCSSpp sh r 2
513 (b) 0 none (b) ON
1537 (c) 46210 CRC Error
Counter (#623)
MAJ
2
OFF
3841 (d) 46208 None
3844 (e) 46223 None
3845 (f) None
3846 (g) TEI None
Continued on next page
Blank This indicates that the Level 1 Status Inquiry failed.
32773 This is a message from the ASAI-Line circuit pack
indicating Level 1 has been deactivated.