Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-109list measurements
8
Output
Field descriptions
list measurements
This command lists performance measurements of a DS-1 link indicating the
quality of the DS-1 physical interface between the system and a far end system.
The ds1 summary option provides a summary report while the ds1 log option
provides a detailed report.
1. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list
marked-ports
print
schedule
Report sent to printer.
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
1
Examples:
list marked-ports
list marked-ports print
list marked-ports schedule
init
inads
craft
cust
rcust
bcms
browse
none none
Port
The port address (cabinet-carrier-slot-circuit) of the marked port.
Board-Type
The type of circuit pack containing the marked port. If this circuit pack
information is no longer available because the circuit pack was
removed after the port was marked, the Board-Type field is blank.
list marked-ports
MARKED-PORT INFORMATION
Port Board-Type
1C0101 DIG-BD
1C0601
1C0702 DIG-BD
Command successfully completed